How to install a radiant barrier under metal roof sheeting
INSTALLATION TIPS

How to install a radiant barrier under metal roof sheeting

The basics of fitting a radiant barrier under roof sheets: air gap, overlaps, taped joints and support, so it performs as tested.

A radiant barrier only works as well as it is installed. These basics apply to most metal-roof sheds, warehouses and PEBs. Always follow your roofing contractor's detail for your particular building.

1. Keep an air gap next to the shiny face

A radiant barrier reflects heat across an air space. If the foil is pressed tight against the hot roof sheet with no gap, heat simply conducts through. The usual approach is to run the barrier over the purlins, so the corrugations of the roof sheet leave an air space above it.

2. Support it between purlins

Over wide purlin spacings, use a support such as wire mesh or straining wire under the barrier, so it does not sag or tear over time. Our FWF and MWM grades are built on woven HDPE fabric with 300–400 N/25 mm tensile strength, so they handle normal installation well.

3. Overlap and tape the joints

Lay rolls with a generous overlap between runs and seal the joints with aluminium foil tape. Gaps let heat through and let moisture-laden air reach the underside of the roof sheet.

4. Run it continuously

Take the barrier right up to the ridge and down to the eaves, and seal around openings and penetrations. Every gap is a spot where heat gets in.

5. Handle it with care

Do not drag rolls over rough ground, and avoid walking directly on the barrier. A clean, undamaged reflective face performs best.

6. Do it at roofing time

The easiest time to fit a radiant barrier is when the roof sheets go on, or when an old roof is re-sheeted. Plan the material with your sheeting order: our standard width is 1200 mm, and regular grades dispatch in about 7 days.

Need roll quantities for your roof area? WhatsApp Ms Lavina on +91 70289 75744 with the length and width of the building.

← More guides from Platinum Polymers

PLATINUM POLYMERS PVT LTD

F-1/3, MIDC Kulgaon, Badlapur (East), Thane 421503, Maharashtra, India

Ms Lavina Fernandes

+91 70289 75744
+91 93222 83776
infopolymers@gmail.com

International business: Platinum Polymers Pvt Ltd USA, 9005 Woodway Dr, Irving, TX 75063 · +1 (817) 424-2992 · mitesh@platinumpolymersusa.com

COOL ROOF is the insulation brand of Platinum Polymers Pvt Ltd.

WhatsApp us